DOD 6055.9-STD PDF

Ammunition and explosives safety standards herein shall be considered minimum and greater protection shall be afforded when practicable. They apply. The Chairman, Department of Defense Explosives Safety Board (DDESB), is today announcing several changes to DoD STD, dated 5. The Department of Defense Explosives Safety Board (DDESB) is announcing Board-approved changes to DoD STD, dated August.

Author: Virisar Fecage
Country: Burma
Language: English (Spanish)
Genre: Relationship
Published (Last): 7 June 2009
Pages: 168
PDF File Size: 18.63 Mb
ePub File Size: 4.20 Mb
ISBN: 502-7-39281-223-3
Downloads: 10879
Price: Free* [*Free Regsitration Required]
Uploader: Talmaran

DOD x9-STD JUL -STD AMMUNITION EXPLOSIVES SAFETY

ICS Number Code It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. It is not in general intended to provide guidance on the protection of structures in the vicinity of where the blast resistant trash receptacles are deployed.

  GEZE IGG PDF

Every facility or venue has unique features associated with factors such as demographics, location, and functions. Blast resistant trash receptacles that meet the requirements of Specification E when subjected to internal explosions equal to or less than the force protection rating contain horizontal primary fragments and do not produce secondary fragments. This effect may cause burns to people caught within or near to the fireball.

Fragments resulting from explosions create the greatest danger to people as fragments may travel several hundred meters and still have velocities that could be lethal or injurious. Historical Version s – view previous versions of standard. The selection of deployment locations impacts both the mitigation 6055.9-std the effects of an explosion occurring within one as well as the convenience of using the receptacles.

Combining values from the two systems may result in non-conformance with the standard.

Referenced Documents purchase separately The documents listed below are referenced within the subject standard but are not provided as part of the standard. It is important, therefore, that blast resistant trash receptacles are not placed near combustible materials. Also, it is possible that 6055.9-ste heat output from an explosion may cause nearby combustible material to ignite. Link to Active This link will always route to the current Active version of the standard.

  ANJOS CABALISTICOS PDF

DoD STD, “DoD Ammunition and Explosives Safety Standards,” 7/

Trash receptacles dd crowded places have been, and continue to be, an attractive repository for explosives. The recommendations in this guide are intended to mitigate the damaging effects of fragmentation and overpressure in crowded places. For example, special security concerns at high value facilities or high pedestrian count venues will require guidance concerning the deployment of blast resistant trash receptacles from security personnel familiar with that facility.

Author: admin